Pressure Reducing and Temperature Reducing Device is the ultimate selection for high pressure and temperature steam reduction service, the system employs many advanced concept and benefits to offer with best solution with effective performance of high pressure and temperature conditions.



Pressure Reducing and Temperature Reducing Device adopted with highly pressure rated forged body of PRV with pilot plug design which gives supreme stability and controlling performance during continuous operation under high pressure and temperature, its design pressure is <14.0 MPa, design temperature is < 570 DegreeC, steam flow range is from 10% to 100%.






DESIGN PRINCIPLE











































































Layout





Assemble Parts




Basic Parameters




Pressure Reducing System




Available inlet pressure: P1<14.0 MPa




Pressure Reducing Valve




Available inlet temperature: T1<570 DegreeC




Orifice Plate




Available Inlet flow rate: 10%~100%








Noise Level: <85 dbA




Desuperheater System




Classical Venturi design




Pressure Class




Custom-design,

Acc to specifications




Double Venturi Design




Multiple Nozzle with Venturi Design




Annular Nozzle with Venturi Design




Size




From DN200 to DN700 (8" to 28")








Additional sizes on request




Feed Water Control System




Design Temperature




Maximal. 570 Degree C

Higher temperature on request




Feed Water Control Valve




Strainer and Globe Valve




Actuator




Pneumatic




Check Valve




Other actuators on request








Electric




Safety System




Installation




Horizontal




Safety Valve




Connection




Flange (ASME B16.5)








Butt weld (Acc to request)




Instruments System




Valves




SA 105




Pressure Gauge




SA 182 F11




Thermometer




SA 182 F22




Pressure Transmitter




SA 182 F91




Thermocouple




Additional Materials on request








Pipes




SA-106B




Others Parts




SA-355 P11




Connection Pipe




SA-355 P22




Counter Flange and Fastens




SA-355 P91








Additional Materials on request




Applications




Apply Standards




Power plant requirements for desuperheated steam




NB/T47033-2013

<Pressure Reducing Desuperheater System>

Manufacturing acc. to ASME

IBR, CE certificated on request




supplying units having limited operating temperatures.




Control steam temperature and pressure to dryers in paper industry and sugar mills industry




Reduction and control of superheated steam,where excess temperatures will harm the product






PRESSURE REDUCING & DESUPERHEATING PART















Basic Control





Main Parts





NY963Y



HP Steam Pressure Reducing Valve



Vital to the safe and efficient operation of a power plant, the NY963/663Y Series pressure reducing valve has been designed for ultimate reliability. It employs many new technology with advanced procession method to ensure the best performance for high pressure and temperature service.





Venturi Concept and Multiple Nozzle



The venturi design is based on a sophisticated concept. The upstream steam comes from venturi chamber with accelerated velocity, which turns the spray water and flows with it through the mixing module where steam and water meld together with very high contacting efficiency. The design brings many advantages including minimal pressure drop, shorter installation length and higher range ability, also there is no moving parts which ensure the stability and low maintenance cost in future operation.





Feed Water Control Valve



The most excellent of cage guided control valve is its balance characteristic, for plug balance port’s function, fluid pressure acted on static unbalance force of plug, it reduced unbalance force, then valve can be configured actuator smaller than conventional control valves.



With balance type characteristic, LT661Y/961Y feed water control valve is designed to focus on high pressure drops, effectively reduce the effects of cavitation and the noise in the high pressure drops services which is especially suitable for feed water application.






(Details please find control valve brochure)




Layout







SIZE AND DIMENSION
































DRAWING




No




Item Name





1




Pressure Reducing Valve




2




Multipe Nozzle




3




Steam Pipeline




4




Safety Valve




5




Pressure Gauge




6




Bimetal Thermometer




7




Globe Valve




8




Strainer




12




Check Valve




11




Feed Water Control Valve




10




Throttle Valve




9




Orifice Plate

































































































No




CODE




PRESSURE REUDCE VALVE




STEAM PIPE OUTLET




WATER CONTROL VALVE




SAFETY VALVE




1




GWY601




DN50




DN50




DN80




DN20




2




GWY601




DN80




DN65




DN100




DN25




3




GWY601




DN100




DN80




DN150




DN32




4




GWY601




DN125




DN100




DN200




DN40




5




GWY601




DN150




DN150




DN250




DN50




6




GWY601




DN175




DN200




DN300




DN65




7




GWY601




DN225




DN250




DN80




8




GWY601




DN250




DN300




DN100




9




GWY601




DN350




10




GWY601




DN400




11




GWY601




DN500




12




GWY601




DN600




13




GWY601




DN700




14




GWY601




DN800











































Multiple Nozzle Technology





Brief

HZVALVE has incorporated the latest technology in the multiple spray nozzle design. The high quality spring loaded nozzle was employed and assembled with desuperheaters to atomize the water droplets and produce the heat transfer contact area necessary for cooling the steam so that to bring steam and water to meld together with very high contacting efficiency.




Principle

The spray water enters the nozzle chamber through multiple tangentially drilled holes, thereby causing water to swirl within the nozzle chamber. The spring, which is pre-compressed to a certain set pressure, keeps the nozzle plug pressed against the seat. As soon as the pressure differential between the water & steam exceeds the set pressure, the plug lifts from its seat and the spray water exits through the small circumferential opening, in the form of a fine mist. Number of nozzles, spring range and spring set pressure is selected based on the process specifications. The spray water quantity is controlled by an external control valve which responds to feedback from a controller and downstream temperature sensor.





No




Part Name




No




Part Name




No




Part Name




1




Adjust Nut




5




Nozzle Body




9




Nut




2




Spring




6




Nozzle Shaft




10




Bolt




3




Nozzle Hole




7




Nozzle Holder




11




Counter Flange




4




Swirl-Chamber




8




Gasket




12




Flange




Features

●The special swirl-chamber, spring-loaded design maintains an excellent spray pattern and atomize water into a very fine mist.

●The high quality surface finish minimises frictional losses, thereby ensuring that the total pressure difference between water and steam is available for atomisation of water.

●Wide range of Kv / Cv values selection are offered by using special nozzlecombinations.

●Set pressure & spring range selection ensures sequential opening of the individual nozzles.

●The nozzle is screwed then seal welded into a nozzle holder, easy to be maintained and replaced.














Multiple Nozzle Technology





Nozzle Testing Device



The company has an adjustable multiple nozzle test device. After the nozzle is polished and assembled, each nozzle will be carried out opening and atomizing testing before installing into desuperheater.



The device is composed of water spray frame, air storage tank, pressure gauge, control device, etc. it can test multi specification and multi series nozzles with different flow rate, so as to ensure that each set of nozzle has undergone strict atomization opening test before leaving the factory, and ensure the excellent atomization effect and reliability of the nozzle.






The conventional opening value is 0.1 ± 0.01Mpa






Over (30%~50%) of opening pressure







The spray water enters the swirl chamber with high velocity, gives an excellent spray pattern to optimizes the cooling liquid particle size and atomize water into a very fine mist so that quick evaporation can take place.



http://www.desuperheating.com/

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]