Yokogawa Pressure Transmitter Feature
  • Flow indication (totalize, actual, percent)
  • Indication of different volume- and mass flow units
  • Second (manual) calibration storing
  • Patented float blocking indication function
  • Signal output damping
  • Error message indication
  • Temperature measurement in the electronic transmitter
  •  

Yokogawa Pressure Transmitter Specifiction

 

 

EJA130A High Static Differential Pressure Transmitter

M Capsule

H Capsule

Range

-100 to 100 kPa
(-400 to 400 inH2O)

-500 to 500 kPa
(-2000 to 2000 inH2O)

Span

1 to 100 kPa
(4 to 400 inH2O)

5 to 500 kPa
(20 to 2000 inH2O)

Accuracy

±0.065%

±0.065%

Degrees of protection

IP67, NEMA 4X, and JIS C0920 immersion proof

Certificates

FM, CENELEC ATEX, CSA, IECEx

Output

4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication

Supply voltage

BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)

Ambient temperature

-40 to 85 deg C (-40 to 185 deg F) (general use type)
-30 to 80 deg C (-22 to 176 deg F) (with integral indicator)

Process temperature

-40 to 120 deg C (-40 to 248 deg F) (general use type)

Maximum working pressure

32 MPa (4500 psi)

Mounting

2-inch pipe mounting

Wetted parts material

Capsule

SUS316L (Diaphragm material is Hastelloy C-276)

Cover flange

SUS316

Housing

Cast aluminum alloy or SUS316 equivalent stainless steel (optional

 